Rent high-voltage cable equipment
Rent high-voltage test sets, cable pulling equipment, diagnostics, fibre tools and site power from Reynard. Use the equipment on its own or with a Reynard operator, for offshore and onshore projects.
Available rental equipment
Dromec EPK-15000-PF Electric Capstan
Rental on request
Dromec EPK-10000-SPF Electric Capstan
Rental on request
Wirescan LIRA® Cable Diagnostics
Rental on request
Mohaupt Mobile HV Test Units
Rental on request
Deep Trekker Pivot Underwater ROV
Rental on request
Skylotec ACX Powered Rope Ascender
Rental on request
Skylotec ICX Powered Rope Ascender
Rental on request
Megger® 15kV Insulation Resistance Tester
Rental on request
DLRO®10HD Low Resistance Ohmmeter
Rental on request
Megger TFX SX-1 Cable Fault Locator
Rental on request
EXFO MAX-720D Quad OTDR Module
Rental on request
Sumitomo T-72C+ Fusion Splicer Kit
Rental on request
Fujikura 90S+ Fusion Splicer
Rental on request
TD120-MC Tan Delta Test Set
Rental on request
Pramac P18000 Generator
Rental on request
Kubota® EPS TDE 20 Generator
Rental on request
B2 HVA120 VLF High-Voltage Test Set
Rental on requestNo equipment items match your search. Try another term or filter.
Equipment for every stage of a cable project
Cable pulling and handling
Electric capstans for controlled cable pulling, with constant-tension control and rope pretensioning. Choose the 15,000 kg unit or the compact 10,000 kg unit, with or without an operator.
Equipment explained: Electric Capstan
High-voltage testing and cable diagnostics
VLF and mobile high-voltage test sets, tan delta diagnostics, line impedance resonance analysis, 15 kV insulation resistance testing, low resistance measurement and cable fault location, for commissioning, maintenance and fault investigation.
- B2 HVA120 VLF High-Voltage Test Set
- Mohaupt Mobile HV Test Units
- TD120-MC Tan Delta Test Set
- Wirescan LIRA® Cable Diagnostics
- Megger® 15kV Insulation Resistance Tester
- DLRO®10HD Low Resistance Ohmmeter
- Megger TFX SX-1 Cable Fault Locator
Equipment explained: VLF Cable Testing, Mobile High-Voltage Test Unit, Tan Delta Testing, Line Impedance Resonance Analysis (LIRA), Insulation Resistance Testing, Low Resistance Ohmmeter (DLRO), Cable Fault Location
Fibre optic testing and splicing
A quad OTDR module for fibre link testing, and fusion splicers from Sumitomo and Fujikura for fibre installation and repair, with or without a technician.
Equipment explained: OTDR (Optical Time-Domain Reflectometer), Fusion Splicer
Site power, access and inspection
Generators for temporary site power, powered rope ascenders for controlled vertical access and a portable ROV for underwater visual inspection.
- Pramac P18000 Generator
- Kubota® EPS TDE 20 Generator
- Skylotec ACX Powered Rope Ascender
- Skylotec ICX Powered Rope Ascender
- Deep Trekker Pivot Underwater ROV
Equipment explained: Site Power Generator, Powered Rope Ascender, ROV (Remotely Operated Vehicle)
How renting equipment from Reynard works
-
Share your project
Tell us which equipment you need, the cable type and voltage level, the location and your planning window.
-
Get a tailored quote
Reynard reviews suitability, accessories and documentation, and quotes the rental around your project.
-
Add support if needed
Rent the equipment on its own, or add an experienced operator, test engineer or technician.
-
Use it on site
Calibration and inspection documents are supplied where relevant, so the equipment is ready for the work.
Frequently asked questions
Can I rent equipment without an operator?
In many cases, yes: equipment-only rental can be discussed per item. For specialist work such as high-voltage testing or cable fault location, experienced support is often recommended, and Reynard can supply it.
What do I need to send to get a rental quote?
Share the equipment you need, the cable type and voltage level, the test objective or application, the site location, your planning window and whether you want operator support.
Can the equipment be used for offshore projects?
Offshore use is reviewed per project. Reynard checks mobilisation, access, lifting, safety documentation and the required support crew before confirming availability.
Which documents are supplied with the equipment?
Calibration records, inspection documents and manufacturer information are available where relevant, and are agreed in the rental request.
How are rental prices and periods set?
Every item is quoted on request. The price and rental period depend on the equipment, the support level and the project timing, so there is no fixed price list.
Does Reynard also test and install cables, not only rent equipment?
Yes. Reynard installs, terminates and tests high-voltage cables for offshore wind and onshore energy projects, so a rental can be combined with a service package.
Equipment explained
New to a piece of equipment? Our glossary explains how each one works, where it is used and what to check before renting.
- Electric Capstan
- Line Impedance Resonance Analysis (LIRA)
- Mobile High-Voltage Test Unit
- ROV (Remotely Operated Vehicle)
- Powered Rope Ascender
- Insulation Resistance Testing
- Low Resistance Ohmmeter (DLRO)
- Cable Fault Location
- OTDR (Optical Time-Domain Reflectometer)
- Fusion Splicer
- Tan Delta Testing
- Site Power Generator
- VLF Cable Testing