B2 HVA120 VLF High Voltage Test Set 120kV
The B2 HVA120 is a VLF high-voltage test set for cable testing applications. Reynard can help determine whether this unit fits the cable system, test standard and project planning.
Description
VLF high-voltage test set for cable testing, commissioning and diagnostic work packages.
The B2 HVA120 is a VLF high-voltage test set for cable testing applications. Reynard can help determine whether this unit fits the cable system, test standard and project planning.
Specifications
- Type: HVA120
- Output voltage: VLF sine wave 0 to 120 kV peak / 0 to 85 kV RMS
- DC output voltage: -100 kV to 100 kV
- VLF square wave: 0 to 100 kV
- Sheath test: 0 to 10 kV negative polarity
- Frequency range: 0.01 Hz to 0.1 Hz
- Output load: 0.5 μF at 0.1 Hz and 85 kV RMS
- Maximum AC current: 56 mA RMS
- Maximum DC current: 80 mA
- Weight: 198 kg / 436.5 lbs
- Cable rating reference: medium-voltage cables up to 69 kV according to IEEE 400.2
- Supplied with: power cable, HV test lead, cable for grounding, USB stick and carrying bag for accessories
- Supplied with: reverse voltage protection, dual discharge device DDD, calibration certificate and necessary software
Features
- Suitable for project-based HV testing support
- Can support commissioning and maintenance workflows
- Available with Reynard testing expertise if required
- Rental request reviewed around cable type, voltage and test objective
Certifications
- Calibration and manufacturer documentation available on request
Frequently asked questions
What is the VLF HVA120 used for?
The VLF HVA120 is used for very low frequency high-voltage testing of cable systems during commissioning, maintenance and diagnostic work packages.
Is the HVA120 suitable for every cable test?
No. Suitability depends on the cable voltage, cable length, capacitance, test standard and project objective. Reynard reviews this before confirming the unit.
Can Reynard provide high-voltage testing specialists?
Yes. The rental request can include Reynard test engineers for preparation, test execution, safety control and reporting.
Which standards can be relevant for VLF cable testing?
VLF testing is often discussed in relation to standards and guidance such as IEEE 400.2. The applicable requirement is confirmed per project.
What documentation is available with the HVA120?
Calibration records, inspection documents and manufacturer information can be discussed and included where available and relevant to the project.
What information is needed to request the HVA120?
Share the cable type, voltage level, route length, test objective, applicable standard, site location, planning window and whether operator support is required.